|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Vopak Terminal
Deer Park Inc. |
|
| VOPAK GCTC -
Deer Park |
|
|
|
| 2759 Independence Pkwy |
|
| Deer Park,
Tx. 77536 |
|
FIRE RETARDANT CLOTHING REQUIRED |
|
| http://www.vopak.com |
|
|
| Main
Telephone: |
281-604-6000 |
|
| Operations
Fax: |
281-604-6095 |
Operations: |
281-604-6055 |
|
| vopak.gctc@vopak.com |
|
| Dock
Coordinators: |
Dispatch |
|
Direct Line: |
281-604-6054 |
|
|
|
Kevin Gafford |
Direct Line: |
281-604-6004 |
kevin.gafford@vopak.com |
|
|
Tim Bielamowicz |
Direct Line: |
281-604-6008 |
tim.bielamowicz@vopak.com |
|
| **
E-Mail Tim or Kevin for scheduling / updates ** |
|
|
|
|
| Insurance
to Kerry Collins |
Direct Line: |
281-604-6043 |
|
|
Fax: |
|
281-604-6100 |
|
| Dock
Information: |
|
|
|
|
|
|
|
DWT |
|
|
|
|
|
| |
|
|
HEADING |
|
CONNECTIONS |
|
PSI@MFOLD |
|
AIR DRAFT |
|
LOA |
BEAM |
DRAFT |
BCM |
SALINITY |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dk. # 1 |
max. Dwt: 60,000 |
Head in / |
|
6 & 8 in |
|
nil |
60m |
900 ft |
125 ft |
40 ft |
|
BW |
|
| |
80,000 if pre-app. |
Portside to |
|
1 x 8" vapor |
|
|
|
|
|
|
|
|
|
|
|
| Dk. # 2 |
max. Dwt: 60,000 |
Head in / |
|
6 & 8 in |
|
nil |
60m |
750 ft |
125 ft |
40 ft |
|
BW |
|
|
80,000 if pre-app. |
|
Portside to |
|
1 x 8" vapor |
|
|
|
|
|
|
|
| Dk. # 3 |
max. Dwt: 60,000 |
Master's |
|
3 x 10" |
|
|
|
nil |
60m |
810 ft |
125 ft |
45 ft |
|
BW |
|
|
80,000 if pre-app. |
|
Option |
|
1 x 6 in vapor |
|
|
|
|
|
| Dk. # 4 |
max. Dwt: 60,000 |
Master's |
|
6 & 8 in |
|
|
|
nil |
60m |
600 ft |
125 ft |
40 ft |
|
BW |
|
|
80,000 if pre-app. |
Option |
|
1 x 6 in vapor |
|
|
|
|
|
|
|
| Dk. # 5 |
max. Dwt: 60,000 |
Master's |
|
6 & 8 in |
|
|
|
nil |
60m |
750 ft |
125 ft |
40 ft |
|
BW |
|
|
80,000 if pre-app. |
|
Option |
|
1 x 6 in vapor |
|
|
|
|
|
|
|
| (min.14
w/3 spring fwd & 3 spring aft) |
|
|
|
|
|
|
* Max.Chnl.Draft / Not berth Draft |
|
| Dock
Facilities: |
|
|
|
|
|
|
|
|
80,000 dwt if approach @
3 inches per second |
|
|
|
|
|
|
|
|
|
|
|
| Gangway
use: |
|
Vsl must provide |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bunkering
via Shoreline: |
No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bunkering
via Barge: |
|
Subject to confirmation |
Karen Pounders Wilson |
karen.wilson@vopak.com |
( CASH UP FRONT ) |
|
|
$ 2,535.58 per barge < in 2012 |
Inside sales / Contracts Mgr. |
fax# 713-561-7344 |
|
|
$ 7,042.28 per operations < in 2012 |
( per
Marpol Wash ) |
|
|
|
Max barge & Ship beam
125 feet @ dock # 1 |
|
rates increase each Jan.
1st / Consumer Price Index |
|
| Ship's
stores at dockside: |
Manually to Dockside |
|
|
Only before / after cargo operations |
No charge stores launch
boat alongside. |
|
| Ship's
stores via barge: |
Yes |
|
|
| Fresh water
available: |
No |
|
via barge only |
|
|
| Slop
Discharge Facility: |
No |
|
via barge only |
Bill Reasoner 281-604-6003 |
|
|
Contractual slops/
Marpol waste by tank truck with prior approval. |
|
| Linehandlers: |
|
Any |
|
Minimum 14
lines |
|
|
| Transit
time from Galveston Seabuoy to All Fast: |
|
|
| Shore Line: |
|
|
| Gate Pass
Required: |
Yes / Company & person's names / fax# 281-479-1341 |
* Fax / e-mail new each morning * |
|
|
e-m: |
vopak.deer.park.guardhouse@vopak.com |
|
PH# 281-604-6045 |
|
|
|
|
|
| COMMENTS: |
1/ |
Certificate of insurance must be on
file |
|
|
2/ |
AMPD coverage: Terminal spill booms only |
|
|
|
Jeff Mats 281-604-6029 |
|
|
3/ |
Terminal requires
free board info. |
|
|
4/ |
FIRE RETARDANANT
CLOTHING REQUIRED - OCT. 01, 2011 |
|
|
| Please
note: this information is correct to the best of our knowledge on Jan. 18, 2010 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|